Over a decade ago, we were the world’s first supplier to commence full-scale production of an electrical coolant pump for main engine cooling – and we haven’t stopped innovating since. Our extensive portfolio offers solutions ranging from the cooling of auxiliary circuits to main cooling of internal combustion engines, batteries, e-motors, and fuel cell stacks. Stationary battery systems, fast charging stations, data centers, and 5G network towers all require thermal management.

Our products make it easy to attain even the most ambitious targets. It doesn’t matter if you use a traditional water-glycol mixture or advanced dielectric fluid, or if you use a low- or high-voltage network – we have the right pump for you!

Our mechanical pump portfolio consists of conventional direct drive pumps that offer a reliable and compact package as well as fully variable pumps, controlled by a solenoid valve for the ultimate combination of reliability and efficiency. All our products are suitable for passenger car and commercial vehicle applications.

 

Portfolio Electrical Coolant Pumps

Portfolio Mechanical Coolant Pumps


Overview Pump Portfolio

WUP 3L

Small Electrical Coolant Pumps

WUP 3L

Highlights

  • Single-phase BLDC motor, hall-sensor controlled
  • PWM communication / LIN interface available
  • Low noise emissions
  • Wet-running pump, no dynamic seals
TECHNICAL DATAWUP 3L
Operating voltage12 V
Flowup to 8 l/min
Pressureup to 0.2 bar
Coolant temperature-40 °C to +125 °C
Current consumption< 1.5 A at 12 V

 


WUP Family

Small Electrical Coolant Pumps

WUP 25L

Highlights WUP 25

  • Wear-free BLDC motor guarantees lifetime of over 9,000 hours
  • 5% improved efficiency reduces power consumption and load on the vehicle’s electrical system
  • 28 dB(A) noise level allows positioning of the pump in the most convenient location
TECHNICAL DATAWUP 25WUP 25 (24 V)
Operating voltage12 V24 V
Flowup to 15 l/minup to 15 l/min
Pressureup to 0.3 barup to 0.3bar
Coolant temperature-40 °C to +130 °C-40 °C to +130 °C
Current consumption< 2.0 A at 12 V< 1.0 A at 24 V

 

Highlights WUP 40 and WUP 60

  • Wear-free BLDC motor guarantees lifetime of over 9,000 hours
  • 5% improved efficiency reduces power consumption and load on the vehicle’s electrical system
  • < 30 dB(A) noise level allows positioning of the pump in the most convenient location
TECHNICAL DATAWUP 40WUP 50
Operating voltage12 V12 V
Flowup to 15 l/minup to 20 l/min
Pressureup to 0.5 barup to 0.6 bar
Coolant temperature-40°C to +90°C (up to 120°C)-40°C to +90°C
Current consumption< 3.3 A at 13.5 V< 4.6 A at 13.5 V

 

Highlights WUP 80

  • Wear-free BLDC motor guarantees lifetime of over 9,000 hours
  • 5% improved efficiency reduces power consumption and load on the vehicle’s electrical system
  • 28 dB(A) noise level allows positioning of the pump in the most convenient location
TECHNICAL DATAWUP 80
Operating voltage12 V
Flowup to 31 l/min
Pressureup to 0.56 bar
Coolant temperature-40 °C to +75 °C
Current consumption< 6.5 A at 24 V

 


CWP Family

Medium Electrical Coolant Pumps

CWP 35

Highlights CWP 35 and CWP 50

  • Low power consumption at high coolant temperatures is perfectly suited for hybrid and ICE vehicles
  • Acoustically optimized design perfectly fits the requirements of hybrid and vehicles with start-stop
  • Lifetime of up to 40,000 hours depending on duty cycle and temperature profile
TECHNICAL DATACWP 35CWP 50
Operating voltage12 V12 V
Flowup to 16 l/minup to 20 l/min
Pressureup to 0.5 barup to 0.6 bar
Coolant temperature-40 °C to +128 °C-40 °C to +128 °C
Current consumption< 3.0 A at 12 V< 4.5 A at 12 V

 

Highlights CWP 65 and CWP 70

  • Low power consumption at low coolant temperatures is perfectly suited for hybrid and electric vehicles
  • Acoustically optimized design perfectly fits the requirements of hybrid and electric vehicles
  • Lifetime of up to 40,000 hours depending on duty cycle and temperature profile
TECHNICAL DATACWP 65CWP 70
Operating voltage12 V12 V
Flowup to 22 l/minup to 31 l/min
Pressureup to 0.7 barup to 0.53 bar
Coolant temperature-40 °C to +90 °C-40 °C to +90 °C
Current consumption< 5.5 A at 12 V< 6.5 A at 12 V

Electrical Coolant Pump for E-Mobility

CWP250

Highlights

  • Extremely low NVH ideally suited for e-mobility
  • Designed for optimum efficiency
  • Supports future diagnostics requirements
  • Modular design easily adaptable to any vehicle application
TECHNICAL DATACWP 150CWP 200
Operating voltage12 V12 V
Flowup to 25 l/minup to 28 l/min
Pressureup to 1.5 barup to 1.7 bar
Coolant temperature-40 °C ... +80 °C-40 °C to +80 °C
Current consumption< 12.5 A at 12 V< 16 A at 12 V
TECHNICAL DATACWP 250
Operating voltage12 V
Flowup to 50 l/min
Pressureup to 1.4 bar
Coolant temperature-40 °C to +80 °C
Current consumption< 20 A at 12 V

CWA Family

Main Electrical Coolant Pumps

CWA 450

Highlights

  • Active cooling of the vehicle electronics minimizes influence of temperature on pump performance
  • Minimum speed below 10% available in step mode for extra precise coolant system control
  • Efficiency of over 50% ensures low power consumption and reduced load on the vehicle’s electrical system
TECHNICAL DATACWA 450CWA 950
Operating voltage12 V48 V
Flowup to 150 l/minup to 189 l/min
Pressureup to 0.9 barup to 1.5 bar
Coolant temperature-40°C to +130°C-40°C to +130°C
Current consumption< 35 A at 13.5 V< 19 A at 48 V

 

High Voltage Coolant Pumps

CWA2000 HV

Highlights

  • No dynamic seals – no aging, high lifetime
  • No external leakage to ambient and electronics – high degree of safety for high voltage, e-motor & inverter
  • Integrated inverter – really low EMC level
  • Fully designed in house – high quality & efficiency
TECHNICAL DATACWA 950 HVCWA 2000 HV
Operating voltage400/800 V400/800 V
Flowup to 189 l/minup to 270 l/min
Pressureup to 1.5 barup to 2.5 bar
Coolant temperature-40°C to +130°C-40°C to +95°C
Current consumption< 1.0 A at 800 V< 4.0 A at 800 V

 

 

 


 

Variable Flow Mechanical Coolant Pumps for Commercial Vehicles

Highlights

  • Integrated electro-hydraulic actuation system < 10 W electric power consumption
  • Fully fail safe – in full flow position
  • Up to 65% less absorbed power consumption compared to mechanical coolant pumps
  • Continuously variable from no flow to full flow
  • 2 kg lighter than other variable concepts
  • High cost-efficiency
Technical Data 
Flow rateup to 1,000 l/min
Pressureup to 5 bar
Actuator typeSolenoid valve
Coolant temperature-40°C to + 120°C
Lifetime2,500,000 actuations

Contact

Do you have any questions about our coolant pumps products? Then get in touch with us using this contact form! We will get back to you soon.

 

HERE you get in touch with us!

Use of cookies and data protection

Rheinmetall Automotive uses cookies saved to your device in order to optimize and continuously improve its websites, as well as for statistical purposes. Further information on our use of cookies can be found here, together with our publication details and data protection notice.

By clicking on “OK” you confirm that you have taken note of the information on cookies, the data protection declaration and the publication details. You can also change your cookie settings for this website at any time.

Privacy settings

We place great importance on transparent information relating to all aspects of data protection. Our website contains detailed information on the settings you can select and what effect these settings have. You can change your selected settings at any time. Regardless of the selection you choose, we will not draw any conclusions regarding you as a person (except where you have explicitly entered your details). For information on deleting the cookies, please see the help function in your browser. You can find out more in the data protection declaration.

Change your privacy settings by clicking on the corresponding buttons

Necessary

Cookies essential for the system ensure that the website works correctly. Without these cookies, malfunctions or error messages may occur.

This website will:

  • Store cookies required by the system
  • Store the settings you make on this website

This site will never do the following without your agreement:

  • Store your settings, such as the language selection or cookie banner, so that you do not have to repeat them in the future.
  • Evaluate visits anonymously and draw conclusions to help us to optimize our website.
  • Draw conclusions regarding you as a person (except where you have explicitly entered your details, e.g. in contact forms)

Convenience

These cookies make the website easier to use and save settings, for example, so that you do not have to repeat them every time you visit the site.

This website will:

  • Store cookies required by the system
  • Store your settings, such as the language selection or cookie banner, so that you do not have to repeat them in the future.

This site will never do the following without your agreement:

  • Evaluate visits anonymously and draw conclusions to help us to optimize our website.
  • Draw conclusions regarding you as a person (except where you have explicitly entered your details, e.g. in contact forms)

Statistics

Statistics cookies enable us to evaluate the usage behaviour on the website anonymously – without enabling any conclusions to be drawn about you as a person. This enables us to measure the performance of the website and to improve it continuously to offer a better user experience.

This website will:

  • Store cookies required by the system
  • Draw conclusions regarding you as a person (except where you have explicitly entered your details, e.g. in contact forms)
  • Evaluate visits anonymously and draw conclusions to help us to optimize our website.

This site will never do the following without your agreement:

  • Draw conclusions regarding you as a person (except where you have explicitly entered your details, e.g. in contact forms)

Of course, we will always respect the do-not-track (DNT) setting in your browser. In this case, no tracking cookies are set and no tracking functions are loaded.